Heat pump or furnace? That is the first thing that matters when the heat quits in Santa Fe, NM, because the two fail in completely different ways. Heat pumps tend to freeze up when defrost stops working, get stuck in cooling when a reversing valve fails, or quietly lean on the electric backup strips, at several times the normal operating cost, when the outdoor unit dies. Gas furnaces usually come down to the flame sensor: once oxide coats it, the burners light but the flame cannot be proven, so the board cuts the gas and locks out after three tries. After that, we most often find cracked hot surface igniters, stuck pressure switches, clogged condensate traps on high-efficiency models, and blower motors at the end of their life.
Most of our service calls are for Furnace Repair. If something has stopped working, start there.
Signs You Need Heating Repair in Santa Fe
Spotting the early warning signs lets you act before the problem gets expensive. Watch for these telltale signs:
- Higher heating bills with less comfort to show for them
- Booming or banging at ignition, a sign of delayed burner light-off
- The system starting and stopping every few minutes without warming the house
- A rotten-egg, burning, or musty smell once the heat kicks on
- The thermostat calls for heat but the vents blow cold air or nothing
- Some rooms warm while others stay stubbornly cold
- Thick ice or frost covering the heat pump outside
- The furnace clicking and trying to light but shutting back down
Act Before It Gets Worse
Most HVAC failures start small, a weak capacitor, a squealing blower, a system that runs a little longer each week. Don't wait, call (505) 230-1922 and we'll take a look right away.